OEM Soil Vacuum Saturation Device Portable Lab Vacuum Air Extractor with 220V for Soil Testing Manufacturers, Supplier

The soil vacuum saturation apparatus is designed and manufactured according to JTG E40-2007, the method for preparing soil samples and specimens, to determine the vacuum saturation of soil.

Product Description

Equipment Composition

System Components

The Vacuum Saturation Test Device consists of a vacuum pump, a shaking device, a vacuum pressure valve, a vacuum pressure gauge, a time relay, soil containers, and switch controls.

Vacuum Saturation Test Device

Technical Parameters

Soil Container Made of plexiglass, 2 pieces, 4300ml * 2
Vacuum Negative Pressure Range -0.1MPa ~ 1 standard atmosphere
Pumping Power 120W
Time Setting 0 ~ 99 hours 99 minutes
Power Supply Voltage 220V
Dimensions 530mm * 500mm * 500mm

Maintenance & Care

Daily & Regular Maintenance
  • Cleaning: After each use, clean the surface and check bolts, terminals, and belt tension.
  • Seals: Inspect O-rings and shaft seals; replace promptly if hardened or cracked.
  • Monthly: Clean the inlet filter; check lubrication oil levels for oil-lubricated models.
  • Quarterly: Test oil viscosity and clean the cooling system (descale water-cooled or dust air-cooled units).
  • Annual: Complete oil change, motor insulation testing, and bearing inspection.
Safety Precautions

Ensure vacuum and water injection valves are closed before use. Open the vacuum valve slowly after starting the pump to avoid oil spraying.

Regularly calibrate pressure sensors. Before long-term shutdown, drain all residual moisture to prevent internal corrosion.

Frequently Asked Questions

What are the soil containers made of?
The soil containers are made of high-quality plexiglass, with a capacity of 4300ml each.
How do I prevent oil spraying when starting the vacuum pump?
To prevent oil spraying, you should start the vacuum pump first and then slowly open the vacuum valve.
What is the vacuum negative pressure range of this device?
The device operates within a range of -0.1MPa to 1 standard atmosphere.
How often should the lubrication oil be replaced?
A complete oil change should be performed annually. However, if the viscosity change exceeds 15% during quarterly testing, it should be replaced immediately.
What should be done before storing the device for a long period?
Before a long-term shutdown, all residual moisture inside the device must be completely drained to prevent corrosion of internal components.
Does the device include a timer?
Yes, it includes a time relay with a setting range of 0 to 99 hours and 99 minutes.